WS-50(50 liters) Small EDI membrane block
EDI (Electrodeionization) is an advanced technology for producing high-purity and ultra-pure water. It combines electrodialysis and ion exchange, using a DC electric field to remove dissolved salts without the need for chemical regeneration. EDI enables continuous operation, high water quality, and eco-friendly performance — making it a reliable and green solution for ultrapure water production.

Modelo | Caudal de agua estándar (L/H) | Caudal de agua mínimo (máximo) (L/H) | Tasa de recuperación (%) | Caudal de agua concentrada (L/H) | Resistencia a la producción de agua (MΩ-cm) | Parámetros de potencia | ||
Rango de corriente (A) | Valor recomendado (A) | Rango de tensión (V) | ||||||
WS-50 | 50 | 30-60 | 60-80 | 40-50 | ≥15 | 0.3-2.0 | 0.3 | 0-50 |
WS-100 | 100 | 60-110 | 60-80 | 40-50 | ≥15 | 0.3-2.0 | 0.3 | 0-50 |
WS-150 | 150 | 90-160 | 60-80 | 40-50 | ≥15 | 0.3-2.0 | 0.3 | 0-100 |
WS-200 | 200 | 120-210 | 60-80 | 40-80 | ≥15 | 0.3-2.0 | 0.4 | 0-100 |
WS-250 | 250 | 150-280 | 60-80 | 40-80 | ≥15 | 0.3-2.0 | 0.4 | 0-120 |
WS-300 | 300 | 180-350 | 60-80 | 80-120 | ≥15 | 0.3-2.0 | 0.4 | 0-150 |
Modelo | Dimensiones | Longitud del orificio de fijación Columna central (mm) | Anchura del orificio de fijación Columna central (mm) | Diámetro del orificio de la base (mm) | Presión de funcionamiento | |||||
L (mm) | W (mm) | H (mm) | Entrada de agua dulce (Bar) | Salida de agua dulce (Bar) | Entrada de agua concentrada (Bar) | Salida de agua concentrada (Bar) | ||||
WS-50 | 160 | 160 | 390 | 85 | 75 | 6 | 1.2-2.0 | 0.8-1.6 | 0.8-1.6 | 0-0.5 |
WS-100 | 175 | 160 | 390 | 95 | 75 | 6 | 1.2-2.0 | 0.8-1.6 | 0.8-1.6 | 0-0.5 |
WS-150 | 200 | 160 | 390 | 120 | 75 | 6 | 1.2-2.0 | 0.8-1.6 | 0.8-1.6 | 0-0.5 |
WS-200 | 215 | 160 | 390 | 120 | 75 | 6 | 1.5-2.0 | 1.0-1.6 | 1.0-1.6 | 0-0.5 |
WS-250 | 230 | 160 | 390 | 145 | 75 | 6 | 1.5-2.0 | 1.0-1.6 | 1.0-1.6 | 0-0.5 |
WS-300 | 250 | 160 | 390 | 175 | 75 | 6 | 1.5-2.0 | 1.0-1.6 | 1.0-1.6 | 0-0.5 |

Remark: The operating pressure and voltage vary with the inlet water quality, temperature, use time, etc. (The manual measurement of the membrane block size has errors, the actual size shall prevail.)
Note:
1. During operation, water should be turned on first and then power on;
2. The concentrated water outlet should be protected by limit;
3. Pressure setting principle: fresh water inlet > fresh water outlet > concentrated water inlet > concentrated water outlet.
Packing:




Get in touch with us
Our team will be happy to respond to you in less than 24 hours.